Device
Compatibility
Match each medication form with the correct delivery device — from oral syringes to insulin pens and inhalers.
What Is Device Compatibility?
A delivery device is any tool used to measure, hold, or administer a medication to a patient. Device compatibility means choosing a device that matches the medication's physical form and intended route of administration.
Key Terms
Form Drives the Device
The Core Rule
For insulin specifically, the device must match the concentration. A U-100 syringe is calibrated so that \( 1 \text{ mL} = 100 \text{ units} \). Using a mismatched syringe makes the printed scale meaningless and risks a dangerous overdose.
Insulin Calibration
A U-100 syringe means there are 100 units per milliliter. To find the volume for a unit dose:
$$ V_{\text{mL}} = \frac{D_{\text{units}}}{100 \text{ units/mL}} $$Oral Syringe vs. Parenteral Syringe
| Oral Syringe | Parenteral Syringe | |
|---|---|---|
| Tip | Catheter tip, no needle | Luer-lock for needle |
| Route | By mouth only | Injection (IM, IV, SubQ) |
| Connection | Cannot attach IV line | Connects to IV tubing |
| Color cue | Often amber / labeled | Clear, standard barrel |
How to Match a Device
Example 1: Pediatric Liquid
A prescriber orders \( 3.5 \text{ mL} \) of amoxicillin suspension for a toddler, by mouth. Which device?
Example 2: Insulin Dose
A patient needs 22 units of U-100 insulin, SubQ. What volume on a U-100 syringe?
$$ V = \frac{22}{100} = 0.22 \text{ mL} $$Example 3: Inhaled Medication
A child with asthma is prescribed an albuterol metered-dose inhaler (MDI) but has poor coordination timing the puff with a breath. What addition improves delivery?
Common Mistakes
Form-to-Device Summary
| Medication Form | Best Device |
|---|---|
| Oral liquid (small dose) | Oral dosing syringe (mL) |
| U-100 insulin | U-100 syringe or insulin pen |
| Injectable (IM/IV) | Luer-lock parenteral syringe |
| Aerosol / MDI | Inhaler ± spacer |
| Eye drops | Ophthalmic dropper |
| Topical cream | Applicator / gloved finger |
Before You Assess
Next: five questions to test your ability to match medication forms with the correct delivery device.
Question 1 of 5
A nurse needs to give \( 2.5 \text{ mL} \) of an oral suspension to an infant. Which device is most appropriate?
Question 2 of 5
A patient is prescribed 30 units of U-100 insulin. What volume does this represent on a U-100 syringe?
Question 3 of 5
Why are oral syringes designed with a catheter tip instead of a Luer-lock?
Question 4 of 5
A young child struggles to coordinate pressing an albuterol MDI while inhaling. What device addition improves drug delivery?
Question 5 of 5
Which form-to-device pairing is incorrect?