01 / 20

Administration
Equipment

Selecting the right syringes, spacers, and filters to deliver medications safely and accurately.

Pharmacy Technician (PTCE)

What Is Administration Equipment?

Administration equipment includes all devices used to measure, prepare, and deliver a medication to a patient. The right choice depends on the route, the dose, and the properties of the drug.

Three Core Categories

Syringes
Measure and inject precise liquid volumes by route (oral, SC, IM, IV).
Spacers
Hold and slow inhaled aerosol so more drug reaches the lungs.
Filters
Remove particles, glass shards, or air from solutions before delivery.

Syringe Anatomy

Plunger Barrel (graduations) Tip / Luer Needle

The Sizing Rule

For a dose \( D \) (in mL), select a syringe whose capacity \( C \) satisfies \( C \geq D \) while minimizing \( C - D \). Example: to draw \( 0.4 \) mL, a \( 1 \) mL syringe is far more precise than a \( 10 \) mL syringe.

Insulin Syringe Units

Insulin syringes are graduated in units, not mL. Standard U-100 insulin contains \( 100 \) units per \( 1 \) mL, so volume is found by:

Example: an order for \( 40 \) units of U-100 insulin equals \( V = \frac{40}{100} = 0.4 \) mL. Always use an insulin syringe for insulin — never a standard mL syringe.

Spacers for Inhalers

MDI Spacer chamber To lungs

Filters: Purpose

Filter Needle
Draws from a glass ampule to trap glass shards. Switch to a new needle to inject.
In-line Filter
Placed in IV tubing to remove particulates and air during infusion.
Micron Size
\( 5\,\mu m \) for particles; \( 0.22\,\mu m \) for sterilizing / bacteria removal.

Key Distinction: Vial vs Ampule

Vial (rubber top) Ampule (glass)
ContainerRubber stopperSealed glass, snapped open
Filter needed?Usually noYes — filter needle
RiskCoring of stopperGlass shards in solution
Best practiceAdd then withdraw airWithdraw with filter, swap needle

How to Select Equipment

1
Identify the route. Oral, SC, IM, IV, or inhaled each needs different devices.
2
Match the dose volume. Choose the smallest syringe that holds the full dose.
3
Check the container. Ampule? Use a filter needle. Vial? Standard needle.
4
Consider the drug. Insulin needs insulin syringes; inhalers benefit from spacers.

Example 1: Insulin Dose

An order reads: 25 units of U-100 insulin, subcutaneous. What equipment and volume?

Example 2: Ampule Draw

You must draw 0.6 mL from a glass ampule for an IM injection. What equipment is correct?

Example 3: Smallest Syringe

A child needs 0.35 mL of an oral suspension. Available: 1 mL, 5 mL, and 10 mL oral syringes. Which is best?

Common Mistakes

✕ Oversized syringe
Using a 10 mL syringe for a tiny dose loses precision and risks error.
✕ No filter on ampules
Injecting glass shards from a broken glass ampule into a patient.
✕ Wrong insulin syringe
Measuring insulin in mL instead of units leads to large dosing errors.
✕ Luer for oral dose
Oral doses must use oral syringes to prevent IV misconnection.

Quick Reference

SituationEquipment
Insulin orderU-100 insulin syringe (units)
Tiny IM/SC doseSmallest syringe (1 mL / tuberculin)
Glass ampuleFilter needle, then swap
IV particulate concernIn-line filter (\( 5\,\mu m \) / \( 0.22\,\mu m \))
MDI for child/elderlySpacer
Oral liquidOral (non-Luer) syringe

Question 1 of 5

An order is for 30 units of U-100 insulin. What volume does this equal?

Question 2 of 5

Which device is required when withdrawing medication from a glass ampule?

Question 3 of 5

To draw 0.45 mL most accurately, which syringe should you choose?

Question 4 of 5

What is the primary purpose of a spacer with a metered-dose inhaler?

Question 5 of 5

Which equipment correctly prevents an oral liquid dose from being connected to an IV line?