Oxygen Therapy and Ventilatory Support - NREMT AEMT Level
- What SpO range is commonly targeted during oxygen therapy for most adults?
- SpO about to . This range ensures adequate oxygenation without risking oxygen toxicity in stable adult patients not at risk for hypercapnia.
- What is the minimum oxygen flow rate for a simple face mask to prevent CO rebreathing?
- At least L/min. Lower flows allow CO2 accumulation in the mask's dead space, increasing rebreathing and potential hypercapnia.
- What is the normal oxygen concentration in room air at sea level?
- Approximately oxygen. Room air consists primarily of nitrogen (78%) and oxygen (21%), with trace gases making up the remainder at standard atmospheric pressure.
- What device delivers the highest and most reliable FiO for a spontaneously breathing patient?
- Nonrebreather mask at high flow. It minimizes room air dilution through one-way valves and a reservoir, achieving up to 90-100% FiO2 in optimal conditions.
- What is the typical oxygen flow rate for a nonrebreather mask in an adult?
- to L/min (keep reservoir inflated). High flow maintains reservoir inflation to deliver near 100% FiO2 by preventing room air entrainment during inhalation.
- What SpO range is commonly targeted for patients at risk of CO retention (COPD)?
- SpO about to . Lower targets prevent suppression of hypoxic respiratory drive in chronic hypercapnic patients, balancing oxygenation with CO2 retention risks.
- Which clinical presentation is a classic indication for CPAP in the prehospital setting?
- Acute cardiogenic pulmonary edema with distress. CPAP reduces preload and afterload while improving oxygenation, alleviating respiratory distress in pulmonary edema from heart failure.
- What is the recommended adult BVM ventilation rate when a pulse is present?
- About breath every to seconds. This rate (10-12 breaths/min) maintains adequate oxygenation and CO2 elimination without causing hyperventilation in patients with a pulse.
- What is the most appropriate immediate intervention for apnea with a pulse?
- BVM ventilations with oxygen. Apnea requires immediate positive pressure ventilation to oxygenate and ventilate until spontaneous breathing resumes or advanced care is available.
- Which airway adjunct is generally preferred when the gag reflex is intact?
- Nasopharyngeal airway (NPA). NPA is better tolerated in semi-conscious patients as it bypasses the oral cavity and does not stimulate the gag reflex as strongly.
- Which oxygen delivery device is preferred when a precise FiO is needed (for example, COPD)?
- Venturi mask (air-entrainment mask). It uses adapters to entrain specific air-oxygen ratios, providing controlled FiO2 (24-50%) ideal for patients sensitive to high oxygen levels.
- Which finding is the most reliable indicator of hypoxemia in the field?
- Low pulse oximetry (SpO) with clinical correlation. Pulse oximetry measures oxygen saturation noninvasively, but must be interpreted alongside clinical signs like cyanosis or altered mental status for accuracy.
- What is the primary clinical goal of oxygen therapy in a hypoxic patient?
- Correct hypoxemia by improving oxygenation. Oxygen therapy aims to increase alveolar oxygen levels to enhance tissue oxygenation in patients experiencing low blood oxygen saturation.
- Identify the most likely cause if SpO is low but the patient has cold hands and poor waveform.
- Poor perfusion causing unreliable pulse oximetry. Peripheral vasoconstriction from shock or cold reduces pulsatile flow, leading to inaccurate SpO2 readings despite potentially normal oxygenation.
- What is the recommended pediatric BVM ventilation rate when a pulse is present?
- About breath every to seconds. Children have higher metabolic rates and oxygen demand, requiring faster ventilation (12-20 breaths/min) to match physiological needs.
- What is the key setup check for a nonrebreather mask before applying it to the patient?
- Reservoir bag inflated and one-way valves functioning. These ensure the device prevents exhaled air re-entry and maintains high FiO2 by storing oxygen for inhalation.
- Which airway adjunct is contraindicated in a patient with an intact gag reflex?
- Oropharyngeal airway (OPA). OPA insertion can trigger gagging or vomiting in responsive patients, risking aspiration, so it's reserved for unconscious individuals without reflexes.
- Find the best immediate correction if BVM ventilations produce no chest rise and high resistance.
- Reposition airway and reseal mask; consider obstruction. Inadequate chest rise indicates failed ventilation, often due to poor seal, airway malposition, or blockage requiring prompt troubleshooting.
- What is the most accurate method to confirm and continuously monitor ventilation effectiveness in the field?
- Waveform capnography (ETCO trending). It provides real-time graphical ETCO2 monitoring, confirming tube placement and assessing ventilation adequacy more reliably than colorimetry.
- What is the typical oxygen flow rate for a simple face mask in an adult?
- to L/min. This range delivers 40-60% FiO2, suitable for moderate hypoxemia, but requires minimum flow to flush exhaled CO2.
- What is the appropriate ventilation rate for an adult with an advanced airway during CPR?
- breath every seconds (about /min). During CPR with an advanced airway, asynchronous ventilations at this rate support circulation without interrupting compressions.
- What is the typical oxygen flow rate range for a nasal cannula in an adult?
- to L/min. This flow provides low to moderate FiO2 (24-44%) comfortably for patients with mild hypoxemia who can breathe spontaneously.
- Which option is most appropriate for a patient breathing /min with shallow breaths and fatigue?
- Assist ventilations with BVM and oxygen. Tachypnea with shallow breaths and fatigue signals impending respiratory failure, necessitating assisted ventilation to improve gas exchange.
- What is the expected duration of each ventilation to reduce gastric inflation and barotrauma?
- Deliver each breath over about second. Slow delivery minimizes peak inspiratory pressure, reducing risks of gastric distension and lung injury from excessive volume or pressure.
- Which condition is an absolute contraindication to CPAP in most EMS protocols?
- Apnea or respiratory arrest. CPAP requires spontaneous breathing to be effective; apnea necessitates ventilatory support like BVM to prevent hypoxia and hypercapnia.