Tracheostomy And Airway Care - NCLEX Pn
- What is the correct action if you note bubbling or crackling under the skin around the trach site?
- Report subcutaneous emphysema to the provider promptly. Indicates potential tracheal perforation or air leak requiring immediate medical evaluation to prevent complications.
- Which action is correct for routine tracheostomy stoma care to reduce infection risk?
- Clean with sterile technique and keep the area dry with a sterile dressing. Removes debris and bacteria while protecting the site to promote healing and prevent infection.
- Which complication is suggested by bright red bleeding from the tracheostomy site?
- Hemorrhage (possible tracheo-innominate fistula). Suggests arterial erosion, a life-threatening emergency needing urgent intervention.
- What is the correct guideline for tracheostomy ties: how should they fit?
- Secure with space for one finger between tie and neck. Balances secure tube placement with prevention of skin breakdown or circulatory compromise.
- What is the recommended maximum suction time per pass for tracheostomy suctioning?
- No longer than to seconds per pass. Limits hypoxia and mucosal trauma by minimizing oxygen deprivation during the procedure.
- What is the priority nursing action for sudden respiratory distress after a new tracheostomy?
- Assess airway patency and suction the tracheostomy. Addresses potential mucus plugs or obstructions as the most immediate cause of acute distress in fresh tracheostomies.
- Which finding indicates an overinflated tracheostomy cuff requiring intervention?
- Tracheal pain or pressure injury signs with no air leak at low volume. Excess pressure causes mucosal damage despite effective sealing, necessitating deflation or adjustment.
- What is the primary purpose of a tracheostomy?
- To maintain a patent airway via a surgical opening in the trachea. Bypasses upper airway obstructions or facilitates long-term mechanical ventilation by creating a direct tracheal access point.
- What is the correct response if a speaking valve is applied while the cuff remains inflated?
- Remove the valve immediately to prevent airway obstruction. Inflated cuff blocks exhalation, causing pressure buildup and potential barotrauma.
- What is the correct action if you cannot pass a suction catheter through a tracheostomy tube?
- Remove and replace the inner cannula; reassess patency. Clearing potential blockages in the removable inner component restores patency without dislodging the outer tube.
- Which assessment finding most strongly suggests tracheostomy tube obstruction?
- Increased work of breathing with decreased airflow through the tube. Indicates partial or complete blockage impeding normal ventilation through the artificial airway.
- Identify the correct suction technique: apply suction on insertion or on withdrawal?
- Apply suction only on withdrawal. Prevents tracheal wall trauma and atelectasis that could occur from suction during insertion.
- What is the main reason humidification is essential for tracheostomy patients?
- To prevent thick secretions and mucus plugging. Compensates for bypassed upper airways, which normally warm and moisten air, to keep secretions thin.
- Which action reduces hypoxemia risk during tracheostomy suctioning?
- Preoxygenate before suctioning. Increases oxygen reserves to compensate for the temporary removal of air during suctioning.
- Which tracheostomy tube component is removed for routine cleaning to maintain patency?
- Inner cannula (if present). Allows easy removal of secretions and debris to prevent obstruction without replacing the entire tube.
- Which position best reduces aspiration risk during oral intake for a stable tracheostomy patient?
- High Fowler position () with swallowing precautions as ordered. Upright positioning uses gravity to aid swallowing and minimize reflux into the airway.
- What is the priority action for suspected tracheo-innominate fistula bleeding?
- Hyperinflate cuff and apply direct pressure; call rapid response. Temporarily controls massive bleeding by compressing the artery while summoning emergency support.
- What is the purpose of the obturator during tracheostomy tube insertion?
- To guide safe insertion by providing a rounded leading edge. Reduces trauma to tracheal tissues by providing a smooth, blunt tip during tube placement.
- Which condition must be met before using a one-way speaking valve (Passy-Muir type)?
- Cuff must be fully deflated. Permits exhalation around the tube through the upper airway for valve function and speech.
- What is the correct immediate action if a tracheostomy tube becomes dislodged in the first hours?
- Call for help and ventilate with bag-mask; do not blindly reinsert. Immature tract risks false passage with blind reinsertion, so prioritize alternative ventilation and expert assistance.
- Which equipment must be kept at the bedside for every tracheostomy patient?
- Obturator and spare tubes (same size and one smaller), plus suction setup. Ensures immediate availability for emergencies like dislodgement or obstruction to maintain airway patency.
- What is the correct method to verify cuff inflation is not excessive?
- Maintain minimal occlusive volume/pressure to prevent leak. Ensures adequate seal for ventilation while minimizing tracheal ischemia and necrosis risks.
- Which tracheostomy tube part prevents aspiration and allows positive-pressure ventilation?
- Inflatable cuff. Seals the trachea to protect against aspiration of secretions and enables effective delivery of ventilated air under pressure.
- Which nursing action best promotes secretion clearance in a stable tracheostomy patient?
- Encourage coughing and provide adequate hydration and humidification. Facilitates natural expulsion of secretions and maintains thin mucus consistency to avoid plugs.
- What is the correct action if a patient with a cuffed tracheostomy cannot speak?
- Deflate cuff only if ordered/appropriate; consider speaking valve when eligible. Allows airflow over vocal cords for phonation while ensuring safety in eligible patients.