Electrophoresis &
Protein Separation
Master the principles of gel electrophoresis, SDS-PAGE, and isoelectric focusing to separate and identify proteins by size, charge, and \( pI \).
What Is Electrophoresis?
Electrophoresis is a laboratory technique that uses an electric field to separate charged molecules, particularly proteins and nucleic acids, through a gel matrix based on their physical properties.
The Driving Force: Electrophoretic Mobility
The speed at which a molecule migrates through the gel depends on its electrophoretic mobility \( \mu \), which balances electric force against frictional drag:
Why This Matters for the MCAT
Electrophoresis appears in MCAT passages involving protein purification, disease diagnosis, and molecular biology experiments. You need to:
SDS-PAGE: Separation by Size
Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) denatures proteins and coats them with uniform negative charge, so separation depends only on molecular weight.
The Linear Relationship in SDS-PAGE
Native PAGE vs. SDS-PAGE
| Native PAGE | SDS-PAGE | |
|---|---|---|
| Denaturation | No: proteins keep native shape | Yes: fully unfolded |
| SDS Added? | No | Yes: uniform negative charge |
| Separation Basis | Size, charge, and shape | Size (MW) only |
| Biological Activity | Preserved | Lost |
| Reducing Agent? | No | Often yes: breaks disulfides |
| Use Case | Study protein complexes, activity | Determine subunit MW |
Isoelectric Focusing (IEF)
IEF separates proteins by their isoelectric point (\( pI \)): the pH at which a protein has zero net charge and stops migrating in an electric field.
2D Gel Electrophoresis
Two-dimensional gel electrophoresis combines IEF (first dimension) with SDS-PAGE (second dimension) to separate proteins by both \( pI \) and molecular weight simultaneously.
Charge, \( pH \), and \( pI \)
Understanding the relationship between pH and protein charge is essential for predicting migration direction in all forms of electrophoresis.
How to Solve Electrophoresis Problems
Example 1: Reading an SDS-PAGE Gel
A protein sample is run on SDS-PAGE with a reducing agent. The standard ladder and sample produce the following gel:
Example 2: Predicting IEF Migration
Three proteins with \( pI \) values of 5.2, 7.4, and 9.1 are loaded onto an IEF gel with a pH gradient from 3 to 11. Where does each protein end up?
Example 3: Native PAGE Complexity
Two proteins, A and B, are run on native PAGE at pH 8.6. Protein A has \( MW = 50 \text{ kDa}, pI = 6.0 \). Protein B has \( MW = 30 \text{ kDa}, pI = 5.0 \). Which migrates faster?
Common Mistakes to Avoid
Technique Summary
| Technique | Separates By | Conditions | Best For |
|---|---|---|---|
| SDS-PAGE | MW only | Denaturing, + SDS | Subunit MW |
| Native PAGE | Size + charge + shape | Non-denaturing | Complexes, activity |
| IEF | \( pI \) only | pH gradient gel | Charge variants |
| 2D Gel | \( pI \) + MW | IEF then SDS-PAGE | Proteomics |
| Agarose Gel | Size (nucleic acids) | Low % gel, native | DNA/RNA sizing |
Question 1 of 5
A protein with a \( pI \) of 6.8 is placed in a gel at \( pH = 8.4 \). In which direction will it migrate?
Question 2 of 5
In SDS-PAGE, why does SDS (sodium dodecyl sulfate) need to be added to the protein sample?
Question 3 of 5
A researcher runs a purified protein on SDS-PAGE without a reducing agent and sees a single band at \( 120 \text{ kDa} \). When the experiment is repeated with a reducing agent, two bands appear at \( 40 \text{ kDa} \) and \( 80 \text{ kDa} \). What can be concluded?
Question 4 of 5
In isoelectric focusing, a protein with \( pI = 5.5 \) is initially placed at a position in the gel where \( pH = 4.0 \). What happens?
Question 5 of 5
Which technique would be most appropriate for determining whether a protein retains enzymatic activity after electrophoretic separation?