01 / 21

Spectroscopy &
Molecular Absorption

Master the principles of how light interacts with matter, from Beer-Lambert Law to interpreting absorption spectra for the MCAT.

MCAT Chemical & Physical Foundations

What is Spectroscopy?

Spectroscopy is the study of how electromagnetic radiation interacts with matter. When light passes through a sample, specific wavelengths are absorbed by molecules, causing electronic, vibrational, or rotational transitions.

The Electromagnetic Spectrum

UV Visible Light IR 200 nm 400 nm 700 nm 2500 nm Higher Energy Lower Energy Electronic transitions Vibrational transitions Rotational transitions

Why Spectroscopy Matters

Identify Molecules
Functional groups absorb at characteristic wavelengths, enabling structural identification
Quantify Concentration
Beer-Lambert Law relates absorbance to concentration for precise measurements
Clinical Applications
Pulse oximetry, blood panels, and drug assays all rely on absorption spectroscopy

The Beer-Lambert Law

\( I_0 \) \( I \) \( b \) Sample conc. \( c \)

Transmittance vs. Absorbance

Transmittance (\( T \))
Fraction of light that passes through: \( T = \frac{I}{I_0} \). Expressed as %T from 0 to 100%.
Absorbance (\( A \))
Logarithmic measure: \( A = -\log_{10} T = \log_{10}\!\left(\frac{I_0}{I}\right) \). Unitless, linear with concentration.

UV-Vis vs. IR Spectroscopy

UV-Vis IR
Wavelength Range 200–700 nm 2,500–25,000 nm
Transition Type Electronic Vibrational
Provides Conjugation, chromophores Functional group ID
Plot X-axis Wavelength (nm) Wavenumber (\( \text{cm}^{-1} \))
Plot Y-axis Absorbance % Transmittance
Beer-Lambert? Yes, directly Less commonly used

Molecular Energy Transitions

Ground State \( S_0 \) vibrational levels Excited State \( S_1 \) Excited State \( S_2 \) UV Visible IR

Applying \( A = \varepsilon bc \) Step by Step

1
Identify known variables. The problem will give you three of the four quantities: \( A \), \( \varepsilon \), \( b \), or \( c \).
2
Convert units. Ensure \( b \) is in cm, \( c \) is in mol/L, and \( \varepsilon \) is in \( \text{L} \cdot \text{mol}^{-1} \cdot \text{cm}^{-1} \).
3
Rearrange and solve. For concentration: \( c = \frac{A}{\varepsilon b} \). For absorbance: \( A = \varepsilon b c \).
4
Check reasonableness. Absorbance typically ranges from 0 to ~2 for valid measurements. Values above 2 suggest the solution is too concentrated.

Example 1: Finding Concentration

A solution has an absorbance of \( A = 0.45 \) at 540 nm. The molar absorptivity is \( \varepsilon = 1500 \;\text{L}\cdot\text{mol}^{-1}\cdot\text{cm}^{-1} \) and the cuvette path length is \( b = 1.0 \;\text{cm} \). Find the concentration.

Example 2: Transmittance to Absorbance

A spectrophotometer reads %T = 25% for a protein solution. What is the absorbance? If the path length is 1.0 cm and \( \varepsilon = 5.0 \times 10^4 \;\text{L}\cdot\text{mol}^{-1}\cdot\text{cm}^{-1} \), what is \( c \)?

Example 3: Reading an Absorption Spectrum

Absorbance Wavelength (nm) 0 0.5 1.0 1.5 300 400 500 600 700 370 nm \( \lambda_{\max,1} \) 540 nm \( \lambda_{\max,2} \)

Chromophores and Conjugation

A chromophore is a molecular group that absorbs UV or visible light. The degree of conjugation (alternating single and double bonds) shifts the absorption to longer wavelengths: this is called a bathochromic shift (red shift).

Isolated C=C
\( \lambda_{\max} \approx 170\;\text{nm} \) (deep UV, not easily observed)
Conjugated Diene
\( \lambda_{\max} \approx 217\;\text{nm} \) (shifted into accessible UV)
Beta-Carotene
\( \lambda_{\max} \approx 450\;\text{nm} \) (11 conjugated double bonds, absorbs blue: appears orange)

Linear Relationship: \( A \) vs. \( c \)

Absorbance Concentration (M) 0 1.0 2.0 0 0.01 0.02 Linear Region Deviation

Common Mistakes to Avoid

✕ Confusing T and A
Transmittance is a ratio (0 to 1), while absorbance is a logarithmic quantity. They are inversely related, not interchangeable.
✕ Ignoring Units
Path length must be in cm and concentration in mol/L for standard molar absorptivity units. Mismatched units give wrong answers.
✕ Color vs. Absorption
A solution's observed color is the complement of what it absorbs. If it absorbs red, it appears green, not red.

Summary of Key Equations

Quantity Equation Key Detail
Photon Energy \( E = h\nu = \frac{hc}{\lambda} \) \( h = 6.63 \times 10^{-34}\;\text{J}\cdot\text{s} \)
Absorbance \( A = \varepsilon bc \) Linear with concentration
Transmittance \( T = \frac{I}{I_0} \) Fraction of light through
A-T Relationship \( A = -\log_{10}(T) \) \( A = 2 - \log_{10}(\%T) \)
Wavenumber \( \bar{\nu} = \frac{1}{\lambda} \) Used in IR (\( \text{cm}^{-1} \))

Question 1 of 5

A solution has an absorbance of 0.60 at its \( \lambda_{\max} \). If the molar absorptivity is \( 2000\;\text{L}\cdot\text{mol}^{-1}\cdot\text{cm}^{-1} \) and the path length is 1.0 cm, what is the concentration?

Question 2 of 5

If the percent transmittance of a solution is 10%, what is the absorbance?

Question 3 of 5

A solution absorbs light most strongly at 450 nm (blue light). What color does the solution most likely appear?

Question 4 of 5

Increasing the conjugation in a chromophore will cause what change in \( \lambda_{\max} \)?

Question 5 of 5

Which of the following is a limitation of Beer-Lambert Law?