Using Experimental Techniques - IB Chemistry

  1. During the titration, the student observes that the endpoint color change (from colorless to pale pink) appears gradually over 10-15 seconds rather than sharply. After adding one additional drop, the solution becomes deep purple. What is the most likely cause of this observation and how should the student proceed?
    Answer: The titration rate is too fast; repeat the titration adding drops more slowly near the expected endpoint When performing redox titrations, the sharpness of the endpoint depends on how quickly you add titrant near the equivalence point. In permanganate titrations, you're looking for the first persistent pale pink color that indicates a slight excess of MnO4−\text{MnO}_4^- ions. The gradual color change over 10-15 seconds followed by a deep purple after one more drop is a classic sign that you're adding titrant too quickly. Near the endpoint, the concentration of Fe2+\text{Fe}^{2+} becomes very low, so each drop of permanganate creates a temporary local excess that takes time to react completely. When you add drops too fast, you can't distinguish between this temporary color and the true endpoint. Option C correctly identifies that slower addition near the expected endpoint will give you a sharper, more accurate endpoint. You should repeat the titration, adding drops rapidly at first, then switching to dropwise addition when you approach the expected volume. Option A is wrong because manganese dioxide (brown precipitate) isn't mentioned in the observations - the student sees purple, which indicates excess permanganate, not MnO2\text{MnO}_2 formation. Option B misses the point since this reaction actually requires acidic conditions (note the 8H+8\text{H}^+ in the equation), and the gradual endpoint isn't due to pH issues. Option D unnecessarily complicates the procedure when the problem is simply technique-related. Study tip: In any titration, when you observe a gradual rather than sharp endpoint, your first thought should be titration technique - specifically whether you're adding titrant too quickly near the equivalence point.
  2. A student synthesizes a solid product via precipitation, collects it by filtration, and washes it with deionized water. The product is then dried in an oven. If the student does not dry the product sufficiently, how will this affect the calculated percentage yield?
    Answer: The percentage yield will be higher than the true value. B is correct. The percentage yield is calculated as (actual mass / theoretical mass) × 100%. If the product is not dried completely, its measured mass will include the mass of the residual solvent (water). This makes the measured 'actual mass' artificially high. A value that is higher than the true mass of the product will lead to a calculated percentage yield that is also higher than the true value. It is common for this error to lead to calculated yields greater than 100%.
  3. During a spectrophotometric analysis, a student prepares a calibration curve using standard solutions. The curve shows excellent linearity (R² = 0.998) from 0.1 to 1.0 mg/L, but when they measure an unknown sample, the absorbance reading is 1.85, which corresponds to 1.4 mg/L on their curve. What is the most appropriate next step?
    Answer: Extend the calibration curve by measuring additional standards up to 1.5 mg/L The unknown sample's concentration (1.4 mg/L) falls outside the calibrated range (0.1-1.0 mg/L). Extrapolation beyond the calibrated range is unreliable even with high R². The best practice is to extend the calibration curve to include the sample's concentration range. Dilution could work but introduces additional error, and Beer's law may not hold at higher concentrations due to chemical or instrumental factors.
  4. During a crystallization experiment, a student dissolves 5.0 g of impure benzoic acid in 100 mL of hot water, then allows it to cool slowly. After filtration, they recover 3.8 g of crystals. Analysis shows the crystals are 98% pure benzoic acid. What can be concluded about the original sample's purity?
    Answer: The purity cannot be determined without knowing the solubility of the impurities in water The purity cannot be calculated without knowing whether the impurities are soluble or insoluble in water. If impurities are highly soluble, they remain in solution and the recovery loss is mainly pure benzoic acid. If impurities are insoluble, they may be retained in the crystals or removed during filtration. The mass recovery alone doesn't indicate original purity without this information.
  5. A student performs an experiment to determine the enthalpy of neutralization of HCl and NaOH in a polystyrene cup. The calculated enthalpy change is found to be less exothermic than the data booklet value. Which of the following is the most likely significant reason for this discrepancy, assuming the concentrations and volumes of solutions are accurate?
    Answer: Heat was lost to the surroundings through the unlidded top of the cup. D is correct because heat loss to the surroundings is the most significant source of systematic error in simple calorimetry. This loss prevents the solution from reaching its theoretical maximum temperature, resulting in a smaller measured ΔT. A smaller ΔT leads to a smaller calculated heat change (Q = mcΔT), and thus a calculated enthalpy change (ΔH = -Q/n) that is less exothermic (less negative) than the true value. While A and C are also sources of error, they are typically less significant in magnitude than the heat lost from an open container over the course of the experiment.
  6. To prepare 100.0 cm³ of a 0.0200 mol dm⁻³ solution from a 0.100 mol dm⁻³ stock solution, a student requires 20.00 cm³ of the stock solution. Which set of glassware provides the highest accuracy for this dilution?
    Answer: A 20.00 cm³ volumetric pipette and a 100.0 cm³ volumetric flask. C is correct. For preparing accurate solutions (indicated by the number of significant figures), the most precise glassware should be used. A volumetric pipette is calibrated to deliver a single, highly accurate volume (e.g., 20.00 cm³). A volumetric flask is calibrated to contain a single, highly accurate volume (e.g., 100.0 cm³). This combination is the standard and most accurate method for performing a dilution. Measuring cylinders (A, B) and conical flasks (D) are not designed for high-precision volume measurements.
  7. A student heats a sample of hydrated magnesium sulfate, MgSO₄·xH₂O, to determine the value of x. After heating, the crucible is allowed to cool on the benchtop before weighing. The anhydrous MgSO₄ is hygroscopic. How would this error affect the calculated value of x?
    Answer: The calculated value of x will be too low. B is correct. The value of x is calculated from the ratio of moles of water lost to moles of anhydrous salt remaining. Moles of water = (initial mass - final mass) / MrM_r(H₂O). Moles of salt = final mass / MrM_r(MgSO₄). If the anhydrous salt is cooled on the bench, it will absorb moisture from the air because it is hygroscopic. This will make the measured 'final mass' of the anhydrous salt higher than its true value. A higher final mass means the calculated mass loss ('mass of water') will be lower. A lower mass of water and a higher mass of salt will both contribute to making the calculated ratio of moles (and thus the value of x) too low.
  8. A student performs a thin-layer chromatography (TLC) experiment. Which procedural mistake will result in the compounds failing to move up the plate?
    Answer: The baseline where the spots are placed is below the level of the solvent in the chamber. A is correct. The principle of chromatography requires the solvent (mobile phase) to move up the plate via capillary action and carry the spotted compounds with it. If the initial spots on the baseline are submerged in the solvent pool at the bottom of the chamber, the compounds will simply dissolve into the pool instead of undergoing the chromatographic separation process on the plate. B would cause poor separation and non-reproducible RfR_f values, but the compounds would still move. C would add extra spots to the chromatogram from the ink. D would make calculating RfR_f values impossible, but separation would have already occurred.
  9. During a gravimetric analysis experiment, a student obtains a mass of 1.2456 g for their dried precipitate using an analytical balance. However, they realize they forgot to pre-dry the filter paper, which typically retains 0.0008 g of moisture per square centimeter. If the filter paper has an area of 78.5 cm², what is the corrected mass of the precipitate?
    Answer: 1.1828 g, by subtracting the total moisture content from the measured mass The measured mass includes both precipitate and moisture from the undried filter paper. Moisture mass = 0.0008 g/cm² × 78.5 cm² = 0.0628 g. Corrected precipitate mass = 1.2456 g - 0.0628 g = 1.1828 g. The moisture must be subtracted because it was included in the measurement but is not part of the actual precipitate.
  10. Which measurement in an acid-base titration typically has the lowest percentage uncertainty, assuming standard class A glassware is used?
    Answer: The mass of the primary standard used to make the standard solution. A is correct. A modern analytical balance can measure mass to ±0.0001 g. For a typical mass of a primary standard (e.g., ~2 g), the percentage uncertainty is extremely small: (0.0001 / 2) × 100% ≈ 0.005%. The uncertainties for glassware are larger. A 250.0 cm³ volumetric flask (C) has an uncertainty of about ±0.12 cm³, giving (0.12 / 250) × 100% ≈ 0.05%. A 25.00 cm³ pipette (B) is about ±0.03 cm³, giving (0.03 / 25) × 100% ≈ 0.12%. A burette reading (D) has two uncertainties (initial and final reading), each about ±0.02 cm³, for a total uncertainty of about ±0.04 cm³ in the titre. For a 20 cm³ titre, this is (0.04 / 20) × 100% ≈ 0.2%. Therefore, the mass measurement is the most precise.
  11. A student is conducting a kinetics experiment by monitoring the disappearance of a colored reactant using a spectrophotometer. They notice that their absorbance readings are gradually decreasing even in a control sample that contains no catalyst. The decrease follows a consistent pattern over 30 minutes. What is the most likely explanation and appropriate correction?
    Answer: Photochemical decomposition is occurring; use a reference cell and subtract its absorbance change from sample readings A consistent decrease in absorbance in a control sample (without catalyst) suggests photochemical decomposition of the colored compound due to exposure to the spectrometer's light source. Using a reference cell with the same solution and subtracting its absorbance change accounts for this effect. Baseline drift would be random, evaporation would increase concentration (increase absorbance), and temperature effects would be irregular.
  12. During the purification of an impure solid by recrystallization, a minimum amount of hot solvent is used to dissolve the crude product. What is the primary reason for using the minimum amount of solvent?
    Answer: To maximize the yield of crystals upon cooling the solution. C is correct. Recrystallization relies on the desired compound being less soluble in the cold solvent. After the compound is dissolved in hot solvent, the solution is cooled to induce crystallization. If an excess of solvent is used, the solution may not become saturated upon cooling, and a significant amount of the desired product will remain dissolved, leading to a low yield. Using the minimum amount of solvent ensures the solution is saturated or near-saturated with respect to the product when it cools, maximizing the amount that crystallizes out. A is related to the hot filtration step, not the amount of solvent. B and D are practical considerations but not the primary chemical reason for this step.
  13. Which experimental technique would be most suitable for monitoring the rate of the following reaction? Zn(s)+H2SO4(aq)→ZnSO4(aq)+H2(g) Zn(s) + H₂SO₄(aq) → ZnSO₄(aq) + H₂(g)
    Answer: Measuring the change in the total mass of the flask and contents over time. C is correct. The reaction produces hydrogen gas (H₂), which escapes from the open flask. This leads to a decrease in the total mass of the flask and its contents. By placing the flask on a balance, this change in mass can be measured over time and used to determine the rate of reaction. A is not ideal because the change in [H⁺] is what drives the reaction, but measuring pH during a vigorous reaction with a solid is difficult. B is also possible as 2H⁺ ions are replaced by one Zn²⁺ ion, changing the conductivity, but C is a more direct and common method. D is incorrect as all reactants and products in solution are colorless.
  14. A student collects hydrogen gas from the reaction of a metal with acid by displacing water in a measuring cylinder. Before reading the volume, the student ensures the water level inside the cylinder is equal to the water level outside. What is the reason for this step?
    Answer: To ensure the pressure of the collected gas is equal to the atmospheric pressure. B is correct. When the water levels inside and outside the collection vessel are equal, the pressures at that level are also equal. The pressure on the outside is atmospheric pressure. The pressure on the inside is the total pressure of the collected gas (hydrogen + water vapour). By equating the levels, the total pressure inside is made equal to the atmospheric pressure. This simplifies the subsequent calculation using the ideal gas law, as the atmospheric pressure can be easily measured with a barometer. A and C relate to other aspects of the experiment (temperature and partial pressure of water) that are not addressed by this specific action. D is incorrect as the ease of reading is not the primary scientific reason for this crucial step.
  15. An aqueous solution contains an organic compound X which is much more soluble in ethyl acetate than in water. Ethyl acetate is immiscible with water and has a density of 0.90 g cm⁻³. To extract X, a student adds ethyl acetate to the aqueous solution in a separating funnel, shakes the mixture, and allows the layers to separate. Which statement is correct?
    Answer: The bottom aqueous layer is run out through the stopcock first. D is correct. Since ethyl acetate has a density (0.90 g cm⁻³) less than water (~1.0 g cm⁻³), it will form the top layer. Compound X will move into this top layer. In a separating funnel, the lower layer is always drained out through the stopcock at the bottom first. The top layer is then either drained through the stopcock or poured out of the top opening. A is incorrect because the ethyl acetate is the top layer. B is incorrect because vigorous shaking is required for efficient extraction. C is incorrect because the bottom layer must be removed before the top layer can be run out through the stopcock.
  16. A student uses distillation to separate a non-volatile solute from a volatile solvent. Where should the thermometer bulb be placed for an accurate measurement of the boiling point of the solvent?
    Answer: At the same level as the side arm leading to the condenser. C is correct. The boiling point is the temperature at which the liquid and vapor are in equilibrium. This temperature is measured on the vapor that is about to enter the condenser to be turned back into a liquid. Placing the thermometer bulb so that its top is level with the bottom of the side-arm opening ensures it accurately measures the temperature of this vapor. A is incorrect; the liquid itself can become superheated, and this would not be the true boiling point. B is too low; it would not measure the temperature of the vapor in equilibrium. D is incorrect as vapor should not be escaping from the top of the condenser.
  17. In an experiment measuring gas production with a gas syringe, a small leak exists around the plunger. How would this fault affect the shape of a graph plotting volume of gas collected versus time?
    Answer: The graph would plateau at a volume lower than the theoretical maximum. D is correct. A leak in the syringe means that some of the gas produced escapes and is not measured. This will affect the measurement throughout the reaction. The measured rate will be consistently lower than the true rate. When the reaction is complete, the total volume of gas collected will be less than the amount actually produced because of the continuous loss. Therefore, the graph of volume versus time will level off (plateau) at a final volume that is lower than the theoretical maximum yield. B is subtly different; the graph will plateau, but the reaction itself continues until a reactant is consumed. The appearance of stopping early is due to the plateauing at a lower volume.
  18. A student needs to separate a mixture of propan-1-ol (boiling point 97 °C) and butan-1-ol (boiling point 117 °C). Which statement best justifies the use of fractional distillation instead of simple distillation?
    Answer: The difference in boiling points (20 °C) is too small for effective separation by simple distillation. A is correct. Fractional distillation is specifically designed to separate liquid mixtures where the boiling points of the components are close (typically < 25 °C difference). The fractionating column provides a large surface area for repeated vaporization-condensation cycles, which enriches the vapor in the more volatile component (propan-1-ol), allowing for an effective separation. Simple distillation would only achieve a partial separation, with the distillate being only slightly enriched in the lower-boiling point component. B is incorrect; simple distillation can separate miscible liquids, just not effectively if their boiling points are close. C is incorrect; fractional distillation is generally slower and requires a fractionating column in addition to a condenser. D is incorrect; the large surface area for separation is a feature of the fractionating column, not the distillation flask.
  19. In a paper chromatography experiment to separate a mixture of amino acids, a polar stationary phase (cellulose) is used with a non-polar solvent. Amino acid X has an RfR_f value of 0.20 and amino acid Y has an RfR_f value of 0.80. Which deduction is correct?
    Answer: Amino acid Y is less polar than amino acid X. C is correct. The RfR_f value is a ratio of the distance travelled by the substance to the distance travelled by the solvent front. A higher RfR_f value (Y = 0.80) indicates the substance travels further with the mobile phase. Since the mobile phase is non-polar, this implies that substance Y is more soluble in it and less attracted to the polar stationary phase. Substances that are more soluble in a non-polar solvent are themselves less polar. Therefore, Y is less polar than X. A is incorrect because Y has the higher RfR_f and is thus more soluble in the non-polar solvent. B is incorrect because Y has a higher RfR_f, meaning it has weaker, not stronger, attraction to the stationary phase. D incorrectly describes the phases.
  20. A student is extracting caffeine from tea using a separatory funnel with dichloromethane and water. After shaking and allowing the layers to separate, they observe three distinct layers instead of two. The middle layer appears cloudy and does not settle completely even after 10 minutes of standing. What is the most appropriate action to take?
    Answer: Add a few drops of saturated salt solution to break the emulsion and improve layer separation When you encounter multiple layers in a liquid-liquid extraction, you're likely dealing with an emulsion—a stabilized mixture where tiny droplets of one phase are suspended in another. This commonly occurs when extracting organic compounds like caffeine because vigorous shaking can create persistent droplets that resist separation. The cloudy middle layer indicates an emulsion has formed between your aqueous and organic phases. To break this emulsion, you need to disrupt the forces stabilizing these tiny droplets and encourage them to coalesce into their respective phases. Adding saturated salt solution (answer D) is the correct approach because the high ionic strength destabilizes the emulsion. The salt ions interact with water molecules and any surface-active compounds that might be stabilizing the droplets, allowing the phases to separate cleanly into two distinct layers. Answer A is incorrect because anhydrous sodium sulfate is a drying agent used to remove dissolved water from organic solvents—it won't break an emulsion or clarify the layers. Answer B won't work because you can't effectively filter an emulsion; the droplets are too small and the mixture will likely clog your filter paper. Answer C assumes you can already separate the layers cleanly, but the whole problem is that the emulsion prevents proper separation—you'd just be transferring the emulsified mixture between containers. Remember: when you see unexpected multiple layers or cloudiness in extractions, think "emulsion first." Salt solutions, gentle swirling (not shaking), or sometimes just patience can resolve most emulsion problems without losing your product.