Lab Techniques
Titration, Spectroscopy, Calorimetry
Master three essential quantitative methods: measuring concentration with titration, identifying substances with spectroscopy, and quantifying heat transfer with calorimetry.
Why Lab Techniques Matter
Chemistry is an experimental science. Three quantitative techniques form the backbone of nearly every analytical lab: they let you determine how much, what kind, and how energetic a reaction is.
Titration: Finding Concentration
In a titration, a solution of known concentration (the titrant) is added to a solution of unknown concentration (the analyte) until the reaction is complete. The equivalence point is where the amount of titrant added is just enough to completely react with all the analyte, according to the reaction's stoichiometry.
The Titration Equation
Spectroscopy: Light Meets Matter
Spectroscopy measures how matter interacts with electromagnetic radiation. When light passes through a sample, certain wavelengths are absorbed. The pattern of absorption is unique to each substance: a molecular "fingerprint."
The Beer-Lambert Law
Because \( A = -\log_{10}\!\left(\frac{I}{I_0}\right) \), we can also write transmittance as \( T = \frac{I}{I_0} \), so \( A = -\log_{10}(T) \). The linear relationship between \( A \) and \( c \) holds when the solution is dilute and monochromatic light is used.
Calorimetry: Measuring Heat
A calorimeter is an insulated vessel that traps heat so we can measure the temperature change caused by a chemical or physical process. The core equation connects heat, mass, specific heat capacity, and temperature change.
The Calorimetry Equation
For an exothermic reaction, the surroundings (water) warm up, so \( \Delta T > 0 \) for the water, but \( q_{\text{rxn}} < 0 \). The key relationship is:
Key Distinctions
| Titration | Spectroscopy | Calorimetry | |
|---|---|---|---|
| Measures | Concentration | Identity / concentration | Heat of reaction |
| Key equation | \( M_a V_a = M_b V_b \) (1:1) | \( A = \varepsilon bc \) | \( q = mc\Delta T \) |
| Signal | Indicator color change | Absorbance of light | Temperature change |
| Apparatus | Burette + flask | Spectrophotometer | Calorimeter |
| Type of data | Volume at end point | Absorbance vs. wavelength | \( \Delta T \) vs. time |
Step-by-Step Problem Solving
Example 1: Titration
A 25.00 mL sample of HCl is titrated with 0.150 M NaOH. The equivalence point is reached after 18.30 mL of NaOH is added. Find the molarity of HCl.
Example 2: Beer-Lambert
A solution has an absorbance of \( A = 0.720 \) at 540 nm. The molar absorptivity is \( \varepsilon = 1200 \;\text{L mol}^{-1}\text{cm}^{-1} \) and the cuvette path length is \( b = 1.00 \;\text{cm} \). Find the concentration.
Example 3: Calorimetry
When 2.50 g of NaOH dissolves in 100.0 g of water in a coffee-cup calorimeter, the temperature rises from \( 22.0^\circ\text{C} \) to \( 28.4^\circ\text{C} \). Find \( q_{\text{rxn}} \) per mole of NaOH.
Reading a Titration Curve
Using a Calibration Curve
Common Mistakes
Question 1 of 5
A 30.00 mL sample of \( \mathrm{H_2SO_4} \) is titrated with 0.200 M NaOH. The equivalence point is at 40.00 mL of NaOH. What is the molarity of \( \mathrm{H_2SO_4} \)?
(Note: \( \mathrm{H_2SO_4} + 2\mathrm{NaOH} \to \mathrm{Na_2SO_4} + 2\mathrm{H_2O} \))
Question 2 of 5
A solution has an absorbance of 0.450 in a 1.00 cm cuvette. If \( \varepsilon = 900 \;\text{L mol}^{-1}\text{cm}^{-1} \), what is the concentration?
Question 3 of 5
In a coffee-cup calorimeter, 150.0 g of water rises from \( 20.00^\circ\text{C} \) to \( 26.50^\circ\text{C} \) when a salt dissolves. What is \( q_{\text{rxn}} \)?
(\( c_{\text{water}} = 4.184 \;\frac{\text{J}}{\text{g} \cdot {^\circ\text{C}}} \))
Question 4 of 5
On a titration curve for a weak acid titrated with a strong base, the pH at the equivalence point is:
Question 5 of 5
Which of the following would cause Beer-Lambert Law to give inaccurate results?