- To what precision is a standard 50 mL buret read?
- To mL (two decimal places), estimating one digit between the 0.1 mL markings.
- Why is a buret rinsed with a small portion of the titrant before it is filled?
- So that leftover water does not dilute the titrant and change its known concentration.
- A calorimeter has a constant of 15 J/°C and its temperature rises by 4.0 °C. How much heat does the calorimeter hardware absorb?
- J, since J.
- Heat leaks out of a coffee-cup calorimeter during an exothermic reaction. Is the measured magnitude of too large or too small?
- Too small. Lost heat makes the temperature rise smaller than it should be, so less heat is recorded.
- How should the liquid level in a buret be read?
- At the bottom of the meniscus, with the eye level with the meniscus to avoid parallax error.
- What criterion is used to choose an indicator for an acid-base titration?
- Its color-change pH range should include the pH at the equivalence point.
- At what wavelength should absorbance be measured when building a Beer-Lambert calibration curve?
- At , the wavelength of maximum absorbance, which gives the greatest sensitivity and least error.
- What does the calorimeter constant (heat capacity of the calorimeter) represent?
- The heat absorbed by the calorimeter itself per degree of temperature rise, in J/°C.
- Fingerprints on the optical faces of a cuvette make the calculated concentration of the sample too high or too low?
- Too high. The smudges scatter and absorb light, so the measured absorbance is larger than the analyte alone would give.
- Why is a blank measured before samples in spectrophotometry?
- It sets zero absorbance for the solvent and cuvette, so the measured absorbance comes only from the analyte.
- An air bubble in the buret tip escapes during a titration. Is the calculated analyte concentration too high or too low?
- Too high. The recorded titrant volume includes the bubble, so it overstates the moles of titrant delivered.
- Why does extra distilled water in the titration flask not change the result of a titration?
- It does not change the moles of analyte present, and the endpoint depends on moles, not on volume.