Identify the correct action if a surface dries before the disinfectant contact time is met.
QUESTION
Which action should you take if you reach across a sterile field with a nonsterile arm?
QUESTION
What is the correct response if a biological indicator (spore test) is positive?
Tap to flip before you grade
ANSWER
Remove items from service and repeat sterilization after evaluation. A positive test indicates sterilization failure, requiring item recall and sterilizer maintenance to ensure safety.