Enzyme Assay Data - Biochemistry
- A crude extract has 1000 total units, and the purified fraction has 300 units. What is the percent yield?
- 30%. Yield is total activity recovered divided by starting total activity.
- What is an enzyme unit (U)?
- The amount of enzyme that converts 1 μmol of substrate per minute under defined conditions.
- What is specific activity, and how does it change during a successful purification?
- Enzyme units per milligram of total protein. It rises as contaminating proteins are removed.
- As a common guideline, about what maximum fraction of substrate may be consumed for a measured rate to count as initial?
- About 10%. Beyond that, falling substrate and rising product make the progress curve bend.
- A fraction contains 200 units of enzyme activity in 4 mg of total protein. What is its specific activity?
- 50 U/mg, from .
- Why are enzyme kinetic parameters estimated from initial rates?
- Early in the reaction substrate concentration is essentially unchanged, and product accumulation, reverse reaction and enzyme inactivation are negligible.
- What does a no-enzyme control measure in an enzyme assay?
- The background rate of nonenzymatic substrate conversion or signal drift, which is subtracted from the enzyme rate.
- Specific activity rises from 2 U/mg in the crude extract to 100 U/mg after a purification step. What is the fold purification?
- 50-fold, from .
- In a coupled enzyme assay, why must the auxiliary enzyme be present in excess?
- So that the auxiliary step is never rate-limiting and the measured signal, such as NADH absorbance at 340 nm, reports the rate of the enzyme under study.
- In a valid initial-rate assay, what happens to the measured rate when enzyme concentration is doubled?
- It doubles. Rate should be directly proportional to enzyme concentration, so a nonlinear result signals an assay problem.
- Why is nonlinear regression to the Michaelis-Menten equation preferred over linear plots for estimating and ?
- Linear transforms distort experimental error, giving heavy weight to the least reliable low-substrate points. Direct fitting weights the data properly.
- An assay gives μM/s with a total enzyme concentration of 0.01 μM. What is ?
- . .